EnviroInsite Forum

Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: Stiff Diagrams


Newbie

Status: Offline
Posts: 1
Date:
Stiff Diagrams
Permalink  
 


I'm using Access for my input data. I was able to make Stiff diagrams after lots of frustration with data input formatting. Then I deleted one well from the Wells table and the Access database no longer works to make Stiff Diagrams. Can you help?



__________________


Senior Member

Status: Offline
Posts: 271
Date:
Permalink  
 

Cindy,

Please zip your Access data file and email it to support@enviroinsite.com.  

Bruce Jacobs



__________________


Senior Member

Status: Offline
Posts: 271
Date:
Permalink  
 

Cindy,

The problem was in the inconsistent case in the media name. I switched the Media values in the Constituents table from “water” to “Water” to make them match the Media values in the Observations table and it seems to work ok now. Let me know if you continue to have a problem.

Sorry about the inconvenience. I’ll look at eliminating the case sensitivity so that won’t be a problem in future releases.

Bruce Jacobs

HydroAnalysis, Inc.
bjacobs@enviroinsite.com